A compatible control system can use RTKsub corrections when installing drainage or grading a field. These jobs depend heavily on vertical accuracy. A tractor following a straight line is not proof that a drain has the required fall.
Work from the project height reference
Check the design elevations, units and height datum with the person responsible for the design. Verify the receiver-to-tool offset and control on a known benchmark before starting. Make an independent level check appropriate to the specified grade, especially where the design fall is small.
Check during the work
Repeat the check after a loss of fix, an equipment change or a significant break. Record the actual levels at critical points such as outlets and connections. The project specification determines whether GNSS machine control alone is adequate.
Check height where the drainage decision matters
Observe known vertical control before collecting design points. Record the antenna height, height reference and units. Repeat a check at the outlet or at another point critical to the design. A line that repeats accurately can still have the wrong elevation reference. Verify that the exported file retains the correct heights before using it for machine guidance.